230-8022A-S07 | WHIRL-SYSTEMS - Rudolf Koller

Electronic control panel type 230-8022A-SXX
230-8022A-S07

to overview
test mark:230-8022A-S07
line voltage
230V 50Hz
nominal current
16 A by cosφ=1
total connected load
3.6 kW
system of protection
IP 55
weight
386 g
blower
ON/OFF
◊ interval
◊ It is possible to select this function through the basic adjustments.
interval: ON/OFF
pump
ON/OFF
◊ interval
◊ It is possible to select this function through the basic adjustments.
interval: ON/OFF
status-LED
status LED: The status of the tub is indicated through the status LED.
dry out
◊ automatic/alt. button
◊ It is possible to select this function through the basic adjustments.
Alt. button: Alternatively it is possible to switch on / switch off the function rewash or dry out with an additional button.
OFF-timer
20 minutes
order num. 230-8022A-S07
2 functions:
type see table

connection possibility for:
dry-running protection sensor
push button with or without LED
heating
Switches on automatically when the jet pump is running.
temperature controller
Only when connected to electronic temperature indicator with adjustable function 012 3321C.
Master: The heater switches on when the temperature falls below the set temperature. If the pump has not yet been activated, it will switch on.
Slave: The heater only switches on when the temperature falls below the set temperature and when the pump is already operating.
zone roller
1-push-operation: one short push of the button changes the sequence or stops the program. A long push of the button puts the program into reference position.
disinfection
Starts through the button disinfection and works then automatically. The bath tub is disinfected after about 35 minutes.
fill water chlorination
While filling the tub an automatic chlorination of the fill water takes place.
rewash
Function is activated, if water was in the bath tub. Starts about 10 minutes after the tub is empty.
Alternatively it is possible to start / stop this function at empty tub with a button. duration of the rewash: 2 minutes
dry out
Starts automatically, if water was in the bath tub. The dry out starts about 20 minutes after the tub is empty.
Alternatively it is possible to start / stop this function with a button. duration of the dry out: 3 minutes
OFF-timer
The running time limiter is activated, when the status indicator reads „Pool ready“ and the control panel registers the first pressing of the button. All whirlpool functions may be used as much, as you desire during the operating period. Upon reaching the running time limit, appliances switch off automatically. Should all functions be switched off during this time, the running time limiter will also reset automatically. The appliances may be immediately switched on after the automatic stop.